Revision as of 15:50, 2 June 2025 by Mmaciejewski (talk | contribs) (Created page with "<span style="display:inline-block; margin-bottom:1em;">← Back to Facility Dashboards</span> == '''Adding and Editing Probes''' == Facility staff can add or edit probes through the Facility Dashboard. Each probe entry is divided into several sections: Basic Information, Operating Temperature Range, and Channels. Channels can include individual nuclei or broadband ranges. === '''Basic Information''' === {| class="wikitable" ! Field !! Descripti...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

← Back to Facility Dashboards

Adding and Editing Probes

Facility staff can add or edit probes through the Facility Dashboard. Each probe entry is divided into several sections: Basic Information, Operating Temperature Range, and Channels. Channels can include individual nuclei or broadband ranges.

Basic Information

Field Description Required
Status Select: Operational, Under Repair, or Decommissioned. Yes
Type Select: Solution or Solid State. Yes
Vendor Select from: Agilent/Varian, Blackfox, Bruker, Doty, JEOL, Home-built, Nalorac, PhoenixNMR, Q One, Tech MAG. Yes
Model Text entry of the probe model. Yes
Serial Number Text entry of the serial number. No
Cooling Type Select: Room Temperature, Helium, or Nitrogen. Yes
Sample Diameter Sample tube diameter in mm. Yes
Field Strength Field strength in MHz (¹H). Yes
Gradients Select: None, Z-axis, or XYZ. Yes
X Gradient Strength In G/cm; required only if XYZ is selected. Conditional
Y Gradient Strength In G/cm; required only if XYZ is selected. Conditional
Z Gradient Strength In G/cm; required if Z-axis or XYZ is selected. Conditional
Status Details Optional text description of probe condition or notes. No

Operating Temperature Range

Field Description Required
From (°C) Minimum operating temperature. Yes
To (°C) Maximum operating temperature. Yes

Channels

Each probe may have one or more channels. Click Add Channel to create a new entry.

Channel Entry Fields

Field Description Required
Channel Number Numerical designation of the channel. Yes
Select Coil Choose: Inner Coil or Outer Coil (radio button). Yes
Cooled Preamplifier Checkbox to indicate presence of cooled preamp. No
Broadband Checkbox to indicate if the channel is broadband. No

If Broadband is selected, additional fields are required:

Broadband Frequency Range

Field Description Required
Minimum Frequency (Nucleus) Select a nucleus from a drop-down to define the lower frequency limit. Yes (if broadband)
Maximum Frequency (Nucleus) Select a nucleus from a drop-down to define the upper frequency limit. Yes (if broadband)

All nuclei with frequencies between the selected range will be associated with the broadband channel.

Otherwise, for non-broadband channels, individual nuclei may be added using the Add Nucleus button. This opens a selection menu to assign one or more nuclei to the channel.

---

Once probe information is completed, use the Save button to store the record. The probe will be listed under the associated spectrometer in the facility’s instrument list.